Maintenance Object Repair Procedures
555-233-123
10-2014
Issue 4 May 2002
be reset via reset board PCSS command. The reset command executes this
test.
Table 10-724.
TEST #53 SAKI Sanity Test
Error
Code
Test
Result
Description/Recommendation
none
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1005
ABORT
Wrong circuit pack configuration to run this test. This error
applies only to DS1 interface circuit packs. It means the DS1
interface circuit pack is providing timing for the system and,
therefore, it cannot be reset without major system disruptions.
1. If the circuit pack needs to be reset, set synchronization to
another DS1 interface circuit pack or the Tone-Clock circuit
pack and try again. Refer to SYNC (Synchronization)
Maintenance documentation.
1015
ABORT
Port is not out-of-service.
1. Busy out the circuit pack.
2. Execute command again.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the Short Test Sequence.
any
NO
BOARD
This is normal if the test is being done when (a) the circuit pack
is not physically in the system or (b) the system is booting up.
Otherwise, there is some inconsistency between the physical
configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of
5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...