E-DIG-STA (Emulated Digital Line)
Issue 4 May 2002
10-723
555-233-123
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and stations
with an emulated digital voice terminal and a linked data module. Stand-alone
data modules and data adaptors in stand-alone mode are not supported by the
TN800 circuit pack. Circuit pack maintenance is covered by E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
Notes:
a. Maintenance personnel has busied out the port in question. Make sure that
the port is released from busyout by using the release port PCSSpp
command.
b. The circuit pack has been removed or has been insane for more than 21
minutes. To clear the error, reinsert or replace the circuit pack.
Table 10-270.
Digital Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
18 (a)
0
busyout port PCSSpp
WNG
OFF
rel port PCSSpp
130 (b)
None
WNG
ON
test port PCSSpp sh
1793 (c)
Voice and Control Local
Loop Test (#13)
MIN/
WNG
2
2
Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
ON
test port PCSSpp l r 3
2049 (d)
NPE Crosstalk Test (#9)
MIN/
WNG
2
ON
test port PCSSpp l r 3
2305 (e)
32770
None
3840 (f)
40965
None
3841 (g)
41029
None
2304 (h)
None
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...