Maintenance Object Repair Procedures
555-233-123
10-1442
Issue 4 May 2002
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
2100
ABORT
Could not allocate necessary system resources to run this test.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
FAIL
The terminal equipment is not connected to the circuit pack.
Some terminal equipment, such as modems, may fail even
when connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in
the error log. If present, refer to “RING-GEN”.
3. Check all of the wiring between the station
equipment and the switch. Then, run the test again.
4. If the test still fails, the set may be defective. Check
the set and replace it, if necessary.
5. Some terminal equipment could fail even when it is
connected properly. If this is the case, disable the
test using the change station extension command
(enter
n
into the
Test
field). Note that this action
also disables Test #35 on this port.
PASS
The station is connected properly. This test may also pass if no
terminal equipment is connected and the terminal is located
very far from the switch. User-reported troubles on this port
should be investigated by using other port tests, by examining
station wiring, or by examining the station.
Table 10-546.
TEST #48 Station Present Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...