ISDN-TRK (DS1 ISDN Trunk)
Issue 4 May 2002
10-989
555-233-123
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals
a maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use status
station or status trunk to determine when the port is available
for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1018
ABORT
Maintenance is disable on this trunk.
1. Enable maintenance by entering “y” in the “Maintenance
Tests?” field on page 2 of the change trunk-group form.
1117
ABORT
A service state audit message is outstanding.
1. Wait two minutes and then try again.
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2020
ABORT
The test did not run due to an already existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the already existing
error.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error.
This will cause noisy and unreliable connections. The
ISDN-TRK is moved to out-of-service/near-end state.
1. Replace the circuit pack.
PASS
The port is able to communicate over the TDM Bus.
Table 10-357.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...