DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-659
555-233-123
Table 10-242.
TEST #145 Misframe Alarm Inquiry Test
Error
Code
Test Result
Description/Recommendation
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
Response to the test was not received within the allowable
time period. This may be due to hyperactivity. Error type 1538
in the error log indicates hyperactivity. The hyperactive circuit
pack is out of service and one or more of the following
symptoms may appear.
1. The DS1-BD tests (such as test 138 and test 139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning
a no board result.
3. busyout and release have no affect on the test results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit pack
are placed into the out of service state. The system will
try to restore the circuit pack within 15 minutes. When
no faults are detected for 15 minutes, the DS1 interface
circuit pack is restored to normal operation. All of the
trunks for the DS1 interface circuit pack are then
returned to the in service state. Hyperactivity is often
caused by the associated facility. In such a case, faults
(such as slips, misframes, or blue alarms) would be
entered in the error log. In addition, many hardware
errors would be logged against the associated trunk
circuits. If the facility is OK and the error occurs again
after 15 minutes, escalate this problem.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...