Management Terminals
555-233-123
3-8
Issue 4 May 2002
5. Enter y in the Disable Following a Security Violation field to disable a login
following a login security threshold violation. Default is
y
.
This field appears when SVN Login Violation Notification is enabled.
6. Enter y in the Access to INADS Port field to allow access to the remote
administration port. Default is
n
.
This field appears when customer super-user access to the INADS Remote
Administration Port is enabled.
7. Enter a password for the new login in the Login’s Password field. A
password must be from 4 to 11 characters in length and contain at least 1
alphabetic and 1 numeric symbol. Valid characters include numbers,
and!&*?;’^(),.:- (the system will not echo the password to the screen as you
type).
8. Re-enter the password in the
Login’s Password
field. The system will
not echo the password to the screen as you type.
9. Enter the number of days (1 to 99) from the current day, that you want the
password to expire, in the
Password Aging Cycle Length
field. If a
you enter a blank in this field, password aging does not apply to the login.
10. Decide whether or not to leave y in the
Facility Test Call
Notification
field. If y is selected, the user receives notification at logoff
that the facility test call feature access code is administered. If you do not
want the notification to appear, set the field to n.
!
CAUTION:
Leaving The facility Test Call administered after logging off poses a
significant security risk.
11. Decide whether or not to leave y in the
Facility Test Call
Notification Acknowledgment Required
field. If y is selected, the
user is required to acknowledge that they wish to logoff while Facility Test
Call is still administered. If you do not want to force the user to
acknowledge, set the field to n. This field appears when
Facility Test
Call Notification
field is y.
12. Decide whether or not to leave y in the
Remote Access Notification
field. If y is selected, the user receives notification at logoff that remote
access is still administered. If you do not want the notification to appear, set
the field to n.
!
CAUTION:
To Leave Remote Access feature administered after logging off poses
a significant security risk if you are using the feature in conjunction
with the Facility Test Call feature.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...