Maintenance Object Repair Procedures
555-233-123
10-526
Issue 4 May 2002
Conference Circuit Test (#7)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The
NPE controls port connectivity and gain, and provides conferencing functions on a
per-port basis. The Conference Circuit Test verifies that the NPE channel for the
port being tested can correctly perform the conferencing function. The NPE is
instructed to listen to several different tones and conference the tones together.
The resulting signal is then measured by a Tone Detector port. If the level of the
tone is within a certain range, the test passed.
Table 10-194.
TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test were not available. The
port may be busy with a valid call. Use the display port PCSSpp
command to determine the trunk group/member number of the port.
Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then the port
is unavailable for certain tests. You must wait until the port is idle
before retesting.
1. If the port status is active but the port is not in use (no calls),
check the error log for error type 1025 (see the Error Log table
for a description of this error and required actions). The port may
be locked up.
2. If the port status is idle, retry the command at 1 minute intervals
for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The system may
be under heavy traffic conditions, or it may have time slots out of
service due to TDM-BUS errors. Refer to the TDM-BUS (TDM bus)
Maintenance documentation to diagnose any active TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic and the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...