Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-416
Issue 4 May 2002
Output
The following example shows the output from the test alarms command (query
form left empty by pressing
ENTER
). The responses display on a test-by-test basis
with one line of data for each test result.
Field descriptions
When encountering errors in preparing a particular object to be tested (not
inserted, contention, etc.), an error message display in the
TEST RESULTS
section of the output form.
ALARM ENTRY
section
Port
Port location of alarmed object (cabinet-carrier-slot-circuit); same
identifier as alarm log
Maintenance
Name
The name of the maintenance object
On Board
Fault detected is on the associated circuit pack (
y
) or off board
(
o
).
Alt Name
Terminal extension numbers or trunk group numbers
Alarm Type
Major, Minor, or Warning
Service
State
Current service state of the station and trunk ports:
RDY
(ready for
service),
OUT
(out of service), or
IN
(in service).
Ack
Whether alarm has been acknowledged by the first and second
OSS telephone numbers, respectively.
test alarms Page 1
ALARM ENTRY
Port Maintenance On Alt Alarm Svc Ack? Date Alarm
Name Brd? Name Type State 1 2 Alarmed Count
01C03 UDS1-BD n WARNING 03/06/16:48 1/4
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C03 UDS1-BD 138 NO BOARD
01C03 UDS1-BD 139 NO BOARD
01C03 UDS1-BD 140 NO BOARD
01C03 UDS1-BD 141 NO BOARD
01C03 UDS1-BD 142 NO BOARD
01C03 UDS1-BD 143 NO BOARD
01C03 UDS1-BD 144 NO BOARD
01C03 UDS1-BD 145 NO BOARD
01C03 UDS1-BD 146 NO BOARD
Testing completed for this object.
press CANCEL to quit -- press NEXT PAGE to continue
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...