Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-34
Issue 4 May 2002
change system-parameters
maintenance
This command specifies and displays scheduled maintenance operations and
maintenance support functions. It also activates and deactivates INADS alarm
origination during repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm
fields so you can restore them later.
2. Change the
Alarm Origination to OSS Numbers
field to “neither.”
3. Change the
CPE Alarm Activation Level
field to none.
4. If daily scheduled maintenance must remain idle during a maintenance
procedure, set the
Start Time
field to a time after the session ends. If
daily Scheduled Maintenance is running and needs to be deactivated, set
the
Stop Time
field to one minute after the current time.
5. Press
Enter
and verify that the screen displays the message:
Command successfully completed
NOTE:
For earlier releases of system software, disable Cleared Alarm
Notification and Restart Notification before submitting the form.
NOTE:
When finished working on the switch be sure to return all fields to
their original settings.
Action/Object
Qualifier
Qualifier
Description
Logins
Defaults
Feature
Interactions
change
system-
parameters
maintenance
Examples:
change
system-parameters
maintenance
init
inads
craft
cust
rcust
none
none
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...