Maintenance Object Repair Procedures
555-233-123
10-902
Issue 4 May 2002
1,2,3
FAIL
The control channel between the processor and the port is not
transmitting properly. This port is not operable.
1. Retry the test.
2. If the failure still occurs, issue busyout and release busy,
and then retest.
3. If the failure is occurring on more than one port on the
board, suspect the board.
4. If the failure is occurring on several boards in the same
carrier, escalate the problem.
5. If the failure still occurs and appears to be isolated to one
port, check all wiring to the set and all set connections.
6. Replace the circuit pack as a last resort.
PASS
Hybrid Line Local Digital Loop Around Test passed. The
control channel is transmitting properly.
1. If complaints still exist, investigate by using other circuit
pack tests, and by examining the station, wiring, and
connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1,
issue busyout board.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure that
there is a valid board inserted.
Table 10-327.
TEST #58 Hybrid Line Local Digital Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...