Maintenance Object Repair Procedures
555-233-123
10-150
Issue 4 May 2002
2. Performing a test board long when the circuit pack is in this state
yields the following abort codes:
■
Ports 1 AND 9 abort Test #206 with code 1024
■
Ports 1 AND 9 abort Test #205 with code 2000
■
Board level Tests #209 and #210 abort with code 1024
3. The save/restore announcements command times out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
■
busyout board PCSS (this command drops all calls in progress on
the Announcement circuit pack)
■
reset circuit pack using the reset board PCSS command
■
release circuit pack using the release board PCSS command
Super Frame Match Inquiry Test (#211)
The super frame is a means by which the SP synchronizes with the 140AY device
on the Announcement circuit pack. If the super frame is not synchronized, the SP
is not able to properly process record/playback requests. Both the SP and the
hardware generate a super frame pulse. When these two pulses are out of synch,
the SP sets a flag to indicate the mismatch. When this test is run, the state of this
flag is returned.
Table 10-49.
TEST #211 Super Frame Match Inquiry
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Response to the test request was not received within the
allowable time period. If Error Type 1538 is present in the Error
Log, follow the maintenance strategy recommended for this
Error Type.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...