PR-MAINT (Maintenance Processor [TN2404/TN790
RISC Systems])
Issue 4 May 2002
10-1379
555-233-123
MTP SAT Loop Around Test (#228)
This test is a nondestructive test. The test places the SAT channel of the MTP into
a loop around mode, and it verifies the data integrity of the channel. Although the
test is nondestructive, it causes loss of keyboard input from the PPN SAT.
Table 10-511.
TEST #228 MTP SAT Loop Around Test
Error
Code
Test
Result
Description/Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1000
ABORT
System software resources required for this test are not
available.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to “STBY-SPE” for a description of these error codes.
2000
ABORT
The response to the test request was not received within the
allowable time period.
2033
2034
ABORT
Internal system error
Port busy
1. Retry at 1-minute intervals a maximum of 5 times.
FAIL
The SAT channel failed the Loop Back Test. The SAT is
probably unusable for administration or maintenance. The
EPN SAT, if available, or remote access can still be used.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit
pack.
NOTE:
If you replace the Processor circuit pack, you
need to obtain a new license file.
PASS
The SAT channel passed the Loop Back Test.
1. If the PPN SAT is not usable, check the SAT itself, along
with the cabling.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...