Maintenance Object Repair Procedures
555-233-123
10-1716
Issue 4 May 2002
ANY
(cont’d.)
FAIL
3. If there are no SYNC or DS1-BD errors and
a. this error was logged against the Tone-Clock circuit
pack that was the current system synchronization
reference at the time (use status synchronization to
determine this), replace this Tone-Clock circuit pack.
NOTE:
Disruption may occur when executing the following
procedures.
b. the Tone-Clock circuit pack you are testing is in Active
mode but does not contain the current system
synchronization reference, switch the synchronization
reference to the Tone-Clock circuit pack under test via
set synchronization PC . Retry the command. If the
error is still present, replace this Tone-Clock circuit
pack.
c. the Tone-Clock circuit pack under test is in Standby
mode, make it active via set tone-clock PC and
switch the synchronization reference to it. Reissue the
command. If the error is still present, replace this
Tone-Clock circuit pack.
PASS
The Tone-Clock circuit pack does not detect any timing slips.
This indicates that the external synchronization timing source
is valid or that the system synchronization reference is a
Tone-Clock circuit pack. The status synchronization
command should be used to verify that the desired
synchronization reference is providing timing for the system.
Table 10-630.
TEST #149 TDM Bus Clock Slip Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...