Maintenance Object Repair Procedures
555-233-123
10-798
Issue 4 May 2002
Any
FAIL
The Expansion Interface circuit pack responded incorrectly or, if it
is the EPN Active Expansion Interface circuit pack, it could not
talk to EPN circuit packs.
1. If the Active Expansion Interface circuit pack in the EPN is
failing and a Standby link exists, switch to the Standby link
using the set expansion-link PCSS command.
2. Repeat the Short Test Sequence.
3. If test continues to fail, reset the Expansion Interface circuit
pack via the reset board PCSS command.
4. If the Expansion Interface circuit pack in the EPN is failing,
check for EPN TDM-CLK, TONE-BD, or SYNC failures in the
Hardware Error Log. Clear any EPN clock-related failures
and repeat the Short Test Sequence.
5. If test continues to fail, replace the circuit pack or transceiver.
PASS
The Expansion Interface circuit pack did respond correctly to the
test. Communication from software to the Expansion Interface
circuit pack is functioning.
1. Refer to other Expansion Interface circuit pack tests if
Expansion Interface Link is not functioning correctly.
0
NO
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board
(error 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If
so, check for hyperactivity (error 1538). If hyperactive, use
the reset board PCSS command.
3. Run the test again. If it fails, the ID chip on board may be
bad. Replace the board and retest.
Table 10-294.
TEST #316 Expansion Interface Control Channel Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...