Maintenance Object Repair Procedures
555-233-123
10-342
Issue 4 May 2002
Resolving memory card alarms
NOTE:
To avoid corrupting files, remove a memory card only when the yellow
“Card-in-use” LED is not glowing.
Follow this list to resolve an alarm on a memory card:
1. Make sure that the “card-in-use” amber LED is out.
2. Remove the memory card from the Processor circuit pack slot.
3. Insert a new, formatted memory card firmly into the Processor circuit pack
slot.
4. Verify the new memory card function (test card-mem).
5. If the alarm persists, replace the Processor circuit pack.
6. Insert a new, formatted memory card firmly into the new Processor circuit
pack slot.
7. Verify the new circuit pack and memory card function (test
network-control long).
8. If the alarm resolves, store the current system translations and
announcements (if applicable) to the memory card (save translation and
save announcements, respectively).
Save Translations Interference
All of the actions used in DEFINITY administration commands are listed in the
table below. The command actions that, while active, interfere with daily
maintenance are also indicated. They are the add, change, duplicate, remove,
and set commands. These commands are frequently used by customer
administrators while performing routine administration of DEFINITY.
Table 10-132.
DEFINITY Command Actions
Likely to Disrupt
Less Likely to Disrupt
add
backup
ping
change
busyout
recycle
duplicate
clear
release
remove
display
reset
set
enable
restore
get
resume
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...