Maintenance Object Repair Procedures
555-233-123
10-1196
Issue 4 May 2002
Data Module Audits Test (#17)
This is a series of six tests that are classified as hardware audits. The processor
sends messages to the on-board microprocessor to perform the following tests.
[G1] The audits run only if the station is in-service.
■
Switchhook Inquiry — This is an update of the processor’s software
records based on the on-hook/off-hook status of the data module.
■
Bad Scan Inquiry — A message is sent uplink that contains a count
generated by certain events relating to the digital loop’s (link) conditions.
This could be an indication of communication problems between the
processor and digital port circuit pack.
■
EPF inquiry — The status of the EPF is sent uplink. EPF is not used for
data modules.
■
ID Request — A request is made to the data module for its status. The data
module sends its configuration information and health information back.
This information is checked and a pass/fail result is provided.
■
Ringer Update — This updates the data module’s ringer state according to
processor records.
■
Translation Update — This is a message normally used with digital stations
to refresh the default value that causes the station to send touch-tones only
in the primary information channel. This test is not used with data modules.
Table 10-447.
TEST #17 Data Module Audits Test
Error
Code
Test
Result
Description/Recommendation
1
ABORT
Switchhook audit timed out.
1. Verify the data module is connected to the PBX and repeat
the test.
2. If the test aborts, replace the data module and repeat the
test.
3. If the test continues to abort, replace the circuit pack and
repeat the test.
2
ABORT
ID request fails, health bit is defective, or no response from
on-board microprocessor.
1. Verify that the correct data module type (PDM versus TDM)
is administered.
2. If the test aborts, replace the data module and repeat the
test.
3. If the test aborts, replace the circuit pack and repeat the test.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...