FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-827
555-233-123
FL-DATA (Flash Data Consistency)
In systems with high or critical reliability, the software and the hard patch update
files are stored in the on-board flash memory in both the Active SPE and Standby
SPE. The translations and announcements are stored in the memory cards in
both the Active SPE and Standby SPE. Flash Data Consistency flags problems
when files become mismatched by monitoring the translations, announcements,
update files, and software vintage number in a High or Critical Reliability PPN
system. If the software vintage numbers on both SPEs are mismatched, a MAJOR
alarm is raised. If the announcement files on both memory cards are mismatched,
a WARNING alarm is raised. For all other problems, a MINOR alarm is raised.
The software vintage can be displayed via the list configuration
software-vintage long command. The Flash Data Consistency Test is run on
system technician command and as part of daily Standby SPE maintenance.
NOTE:
Flash Data Consistency is not applicable to Standard systems.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm Level
Initial Command to
Run
Full Name of MO
FL-DATA
MAJOR
test card-mem a|b l
Flash Data Consistency
FL-DATA
MINOR
test card-mem a|b l
Flash Data Consistency
FL-DATA
WARNING
test card-mem a|b l
Flash Data Consistency
Table 10-302.
Flash Data Consistency Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test card-mem a/b l
8 or 16
8 or 16
Flash Data Consistency
Test (#421)
WNG
OFF
test card-mem a/b
1-3,
9-10,
17-18,
32-34,
40-42,
48-50,
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...