MAINT (EPN Maintenance Circuit Pack)
Issue 4 May 2002
10-1033
555-233-123
For single Expansion Links in the EPN:
1. Replace the EPN Maintenance circuit pack, and run the
test again. If it passes, the problem is with the EPN
Maintenance circuit pack.
2. If the test fails, replace the Expansion Interface circuit
pack. If the tests passes, the problem is with the
Expansion Interface circuit pack.
3. If the test still fails, the problem is with the serial link wired
into the backplane of carrier A.
Table 10-374.
TEST #306 EPN Maintenance CP Reset Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page