Maintenance Object Repair Procedures
555-233-123
10-1302
Issue 4 May 2002
s. Error 3329 indicates that the TDM clock has failed (TONE-BD and
TDM-CLK alarms). Refer to TDM-CLK and/or TONE-BD for further action.
The Packet Interface is taken out of service when this failure occurs.
1. Execute the reset packet-interface command to bring the Packet
Interface back into service.
t. Error 3585 indicates a Packet bus failure. Refer to the Packet Bus
maintenance documentation for further action.
u. Error 3841 indicates that the Packet Interface has reported a fatal fault
failure condition that may be caused by a Packet Bus failure on the
Processor Port Network.
1. If Error Type 3585 has also been reported, refer to PKT (Packet
Bus) maintenance. After the Packet Bus failure has been corrected,
bring the Packet Interface back into service (reset
packet-interface).
2. If Error Type 3585 has not been reported, enter the reset
packet-interface command and follow the repair steps associated
with test #889.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Packet Interface Private Looparound test for
example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
Short
Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Packet Interface Reset Test (#889)
X
D
Packet Interface Private Looparound
Tests (#885)
X
ND
Packet Interface Maintenance
Looparound Test (#886) (a)
X
X
ND
Packet Interface Memory Checksum
Test (#884)
X
ND
Packet Interface Error Counter Read
and Clear Test (#887)
X
X
ND
Packet Interface Active-Standby Peer
Link Test (#888) (b)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...