ISDN-TRK (DS1 ISDN Trunk)
Issue 4 May 2002
10-977
555-233-123
ISDN-TRK (DS1 ISDN Trunk)
A DS1 ISDN Trunk is known as a B-channel. It is a 64 kbps Bearer channel that
can be used to transmit digital traffic, be it voice or data. These trunks use a
separate channel for signaling (for example, for call setup); this mode of operation
is known as out-of-band signaling, as opposed to in-band, robbed-bit signaling,
where the signaling traffic flows over the same channel as the voice or data traffic.
The separate signaling channel is called a D-channel in ISDN terminology, and it
carries all the call control signaling messages for the DS1 ISDN Trunk
B-channels. The D-channel for these B-channels is an ISDN-PRI (Primary Rate
Interface) Signaling Link Port (ISDN-LNK/ISDN-PLK).
On 24-channel interfaces, any of the first 23 ports on the DS1/UDS1 interface
circuit pack can be a B-channel. The 24th port may be used as a B-channel or as
a D-channel depending on the type of ISDN-PRI Signaling Group (ISDN-SGR) to
which it belongs. On 32 channel interfaces, any of ports 1-15 and 17-31 on the
DS1 interface circuit pack can be a B-channel. The 16th port may be used as a
B-channel or as a D-channel depending on the type of ISDN-PRI Signaling Group
(ISDN-SGR) to which it belongs. For more details, refer to the ISDN-SGR and
DS1-BD/UDS1-BD Maintenance documentation.
NOTE:
If a Packet Control circuit pack is used instead of a Processor Interface Link
as the interface of the PBX SPE to the D-channel, then the signaling link
port on the UDS1 circuit pack is referred to as ISDN-PLK and only the
TN464C or later may be used to carry D-channel Signaling. The B-channels
may be carried by any DS1/UDS1 interface circuit pack. If a Processor
Interface is used for connectivity then the Signaling Link port is referred to
as a ISDN-LNK and the TN767 or TN464B or later DS1 interface circuit pack
may be used to carry D-channels Signaling.
For interfaces using country protocol 1 on the DS1 Circuit Pack administration
form (including US), the signaling protocol used for the maintenance of the
B-channel is defined by the AT&T ISDN-PRI Specification.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to
Run
Full Name of MO
ISDN-TRK
1
1
For additional repair information, refer to the
‘‘DS1-BD (DS1 Interface Circuit Pack)’’
maintenance object.
MAJOR
2
2
A MAJOR alarm on a trunk indicates that alarms on these trunks are not
downgraded by the set options command and that at least 75 percent of the trunks
in this trunk group are alarmed.
test port PCSSpp l
DS1 ISDN Trunk
ISDN-TRK
MINOR
test port PCSSpp l
DS1 ISDN Trunk
ISDN-TRK
WARNING
test port PCSSpp sh
DS1 ISDN Trunk
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...