Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-70
Issue 4 May 2002
If the object associated with the specified extension is not a PRI endpoint, the
following message appears:
Extension assigned to object other than pri-endpoint
If the board that contains the PRI endpoint is not inserted in the system, the
following message appears:
Board not inserted
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
extension 22501 are in cabinet 1, carrier B, slot 20, circuit 1 to 6.
release sp-link
Help Messages
If the system technician presses
HELP
after entering “release sp-link,” the following
appears:
Entry is not required
Error Messages
If the system printer link is not administered, the following message appears:
Link not administered or not enabled
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then
resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...