DIOD-DS1 (DS1 DIOD Trunk)
Issue 4 May 2002
10-585
555-233-123
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Hardware Error Log Entries and Test to Clear
Values
out-of-service
The trunk is in a deactivated state and cannot be
used for either incoming or outgoing calls.
in-service
The trunk is in an activated state and can be
used for both incoming and outgoing calls.
disconnect (ready-for-service)
The trunk is in an activated state but can only be
used for an incoming call.
Table 10-217.
DS1 DIOD Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk <grp>/<mbr>
1(a)
57408
1(a)
57487
57476
57477
57485
15(b)
Any
Port Audit and
Update Test (#36)
18(c)
0
busyout trunk
<grp>/<mbr>
WARNING
OFF
release trunk <grp>/<mbr>
130(d)
None
WARNING
ON
test trunk <grp>/<mbr>
257(e)
57392
DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
513(f)
57393
DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
2
OFF
769(g)
57484
1025(h)
51200
1025
DS1 CO Dial Tone
Seizure Test (#314)
MIN/
WRN
3
OFF
test trunk <grp>/<mbr> r 2
1281
Conference Circuit
Test (#7)
MIN/
WRN
3
ON
test trunk <grp>/<mbr> l r 4
1537
NPE Crosstalk Test
(#6)
MIN/
WRN
3
ON
test trunk <grp>/<mbr> l r 3
1793(i)
test board PCSS l
2049(j)
57473
57474
57475
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...