Maintenance Object Repair Procedures
555-233-123
10-720
Issue 4 May 2002
FAIL
The handshake to one of the Duplication Interface circuit
packs has stopped. The circuit pack may be defective or
communication to the circuit pack is hampered.
1. Look in the Hardware Error Log for error types against
TAPE. If TAPE error types are present, resolve them since
TAPE error types can cause Test #315 to fail. Refer to
TAPE Maintenance documentation for recommended
repair strategy.
2. After any TAPE error types are resolved, issue the test
duplication-interface command on the suspect
Duplication Interface circuit pack. If Test #315 fails on
Duplication Interface A, Duplication Interface A is
defective. Replace the Duplication Interface A circuit pack.
If Test #315 fails on Duplication Interface B, Duplication
Interface circuit pack A or Duplication Interface circuit
pack B may be defective. In this case, it is necessary to
determine which Duplication Interface circuit pack (A or B)
is the defective one. To do this, issue the test
duplication-interface A command. If Test #280 fails on
Duplication Interface A, (and Test #315 has just failed on
Duplication Interface B), Duplication Interface circuit pack
A is defective and should be replaced. If Test #280 passes
on Duplication Interface A (and Test #315 has just failed
on Duplication Interface B), replace the Duplication
Interface circuit pack B.
3. Reissue the test duplication-interface command on the
Duplication Interface circuit pack that was replaced. If Test
#315 still fails, check for problems with the Inter-Carrier
Cables (ICCs). If any of the ICCs is defective, replace it.
4. Rerun the test.
NO
BOARD
The Duplication Interface circuit pack has failed to handshake
with either the active Maintenance/Tape Processor (in the
case of Duplication Interface circuit pack A) or with Duplication
Interface circuit pack A (in the case of Duplication Interface
circuit pack B).
1. Follow the FAIL directions above.
PASS
The tested Duplication Interface circuit pack is present and
sane enough to handshake.
Table 10-269.
TEST #315 Duplication Interface Circuit Pack
Status Query Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...