
Maintenance Object Repair Procedures
555-233-123
10-1186
Issue 4 May 2002
Notes:
a. Could experience a noisy port or link. This is an off-board problem detected
by the port circuit. Check for faulty wiring, check for a defective data
module, or reduce the cabling distance between the data module and the
PBX (5000 feet for 24-gauge wire and 4000 feet for 26-gauge wire; see
Note). If the problem still exists, replace the circuit pack. Once the problem
has been resolved, the alarm is retired automatically within 60 minutes.
The DA module is not phantom-powered from the port and hence its range
is limited by the Italtel digital phone’s limit (0.7 km, 2300 feet, on 26-gauge
wire or 1.8 km, 5900 feet, on 22-gauge, 0.6 mm, wire) if in linked mode, or
by the maximum length of loop allowed from the Digital Line Interface (DLI)
component (up to 3.5 km, about 2 miles, with 22-gauge, 0.6 mm, wire) if in
stand-alone mode.
NOTE:
Refer to the DEFINITY Communications System Generic 1 and
Generic 3i Wiring, 555-204-111.
b. This error type and auxiliary data occur when at least 15 off-board
problems have been detected with the link to the data module. When an
error with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for faulty wiring, check for a faulty data
module, or reduce the cabling distance between the data module and the
PBX (5000 feet for 24-gauge wire and 4000 feet for 26-gauge wire; see the
next Note). If the problem still exists, replace the circuit pack. Once the
problem has been resolved, the alarm is retired automatically within 60
minutes.
The DA module is not phantom-powered from the port and hence its range
is limited by the Italtel digital phone’s limit (0.7 km, 2300 feet, on 26-gauge
wire or 1.8 km, 5900 feet, on 22-gauge, 0.6 mm, wire) if in linked mode, or
by the maximum length of loop allowed from the Digital Line Interface (DLI)
component (up to 3.5 km, about 2 miles, with 22-gauge, 0.6 mm, wire) if in
stand-alone mode.
NOTE:
Refer to the DEFINITY Communications System Generic 1 and
Generic 3i Wiring, 555-204-111.
c. This is an internal type error that occurs when an audit request fails.
d. This error type is logged when the port in question is busied out by
maintenance personnel. Make sure that the port is released from busyout.
e. There are problems with transmitting to the data module. This is usually an
on-board problem and can be ignored if no user complaints are received.
Otherwise, check for faulty wiring.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...