
Maintenance Object Repair Procedures
555-233-123
10-102
Issue 4 May 2002
Table 10-35.
TEST #47 Loop Around and Conference Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
7
ABORT
The port was seized by a user for a valid call.
1. Enter display port PCSSpp to determine the station’s
extension. Enter status station extension to determine
the service state of the port. If the port is in use, it will be
unavailable for certain tests. Wait until the port is idle
before retesting.
2. If the port is idle, retry the command at 1-minute intervals
up to 5 times.
1000
ABORT
System resources required to run this test were not available.
The port may be busy with a valid call. (This could be a
Music-on-Hold port.)
1. Enter display port PCSSpp to determine the station’s
extension. Enter status station extension to determine
the service state of the port. If the port is in use, it will be
unavailable for certain tests. Wait until the port is idle
before retesting.
2. If the port is idle, retry the command at 1-minute intervals
up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
“TDM-BUS (TDM Bus)” Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...