EXT-DEV ADMIN? Y (External Device Alarm)
Issue 4 May 2002
10-823
555-233-123
Hardware Error Log Entries and Test to Clear
Values
NOTE:
The loss of -48 volt power will prevent detection of an external device alarm.
AC-POWER, CARR-POW, and DC-POWER alarms could indicate the loss
of the external device alarm -48 volt power source. ALARM-PT alarms may
also indicate a loss of power. When analog line ports are administered as
analog line external device alarms loss of -48 volts will prevent detection of
an external device alarm.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Battery & Battery
Charger Query Test, you may also clear errors generated from other tests in the
testing sequence.
Table 10-300.
EXT-DEV ADMIN? Error Log Entries and Test to Clear Values
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
0
Any
Any
Any
test eda-external-device-alrm
physical location r 2 or 6
1 or 5
Any
External Device
Alarm Test (#120)
Any
OFF
test eda-external-device-alrm
physical location r 2 or 6
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
External Device Alarm Test (MAJOR port) (#120)
X
X
ND
External Device Alarm Test (MINOR port) (#120)
X
X
ND
External Device Alarm Test (WARNING port) (#120)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...