Maintenance Object Repair Procedures
555-233-123
10-1422
Issue 4 May 2002
Table 10-535.
TEST #82 Processor Non-maskable Interrupt Test
Error
Code
Test
Result
Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
FAIL
The interrupt was not detected or acted upon.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, the Processor circuit pack should
be replaced. (Note that if you replace the Processor circuit
pack, you need to obtain a new license file.)
!
WARNING:
If the TN786B circuit pack [386 systems only] must be
replaced, and if there is a blank in the Expansion Memory
circuit pack slot (that is, in the slot immediately to the right
of the TN786B circuit pack), remove the blank before
removing the circuit pack. Otherwise, the circuit pack
and/or the two connectors that are used to connect the
Expansion Memory circuit pack (if available) might become
damaged.
3. If replacement of the Processor circuit pack still results in test
failure, the following circuit packs should be replaced, one at
a time in the order provided: TN770 Memory [G3iV1.1-286
only] Expansion Memory [G3iV2-386 only] TN765 Processor
Interface, TN777B Network Control, TN778 Packet Control,
and TN772 Duplication Interface circuit packs. The test
should then be repeated.
4. If the test still fails after you replace all the circuit packs
discussed in the previous step, the problem must be in the
control carrier, and the carrier should be replaced.
PASS
The interrupt was correctly detected. The 80286/386 CPU chip is
functioning correctly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...