TAPE (Tape Unit) [G3iV1.1-286]
Issue 4 May 2002
10-1625
555-233-123
Tape Translation Status Test (#505)
This test checks whether the TAPE is currently alarmed due to the failure of a load
translation or save translation attempt on the TAPE.
Table 10-601.
TEST #505 Tape Save Translation Status Test
Error
Code
Test
Result
Description/Recommendation
1029 to
1030
and
2011,
2013
to
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance
documentation for a description of these error codes.
2012
ABORT
1. Do the steps below following the directions in the
Maintenance and Repair Procedures’’
section.
2. Issue the test tape long command. If the test passes,
issue the save translations command to verify condition
is clear.
3. If the test fails, make sure tape is fully inserted.
4. If the test continues to fail, clean the tape head and
retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit, use original tape and
retest.
FAIL
The tape is currently alarmed because a save translation or a
load translation attempt failed on this tape. Look for Errors
Types #3329, #3841, #3842, and #3843 in the Hardware
Error Log and resolve these errors by following the
procedures provided in the “Hardware Error Log Entries and
Test to Clear Values” section.
PASS
The last load translation and (if any) save translation attempts
were successful on this tape.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...