UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1853
555-233-123
y. Error Type 3840 — is not service-affecting. No action is required. These
errors are reported by the circuit pack when it receives a bad control
channel message from the switch. The auxiliary data identifies the
following error events:
z. Error Type 3841 — The UDS1 Interface circuit pack has detected a
transient hardware logic error (for example, program logic inconsistency).
This error will disappear when no faults are detected for 100 minutes. The
value in Aux Data indicates the type of hardware problem.
aa. Error Type 3842 — Bad Translation RAM Location Found Error. This error
is not service-affecting. No action is required. A Bad Translation RAM is
detected, but the call continues by using another translation location.
ab. Error Type 3843 — LAN Receive Parity Error. This error occurs when the
circuit pack detects an error in a received frame from the Packet Bus.
These errors are most likely caused by a Packet Bus problem, but may be
due to a circuit pack fault.
Refer to the PKT-BUS Maintenance documentation to determine if the
problem is isolated to this circuit pack or if the problem is caused by Packet
Bus faults.
ac. Error Type 3900 — is used to give status information on a CPE Loopback
Jack Test. The value in the Aux Data field indicates the status of the
loopback test.
Aux Data
Event
4096
Bad major heading
4097
Bad port number
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link
Aux Data
Test Status
1
Currently running
2
Failed because loopback could not be activated
3
Failed because test pattern could not be detected
4
Terminated
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...