Maintenance Object Repair Procedures
555-233-123
10-2016
Issue 4 May 2002
1018
ABORT
There are not any translated ports on the circuit pack, or if there
are ports, then none are administered to have “neon.”
1. Verify that there are ports administered on the circuit pack. If
no ports are administered, no further action is required.
2. Make sure a TN755 or TN752 power unit circuit pack is
installed.
3. Verify that you have neon sets connected (AT&T sets that
may be neon sets are 500 and 2500 series, also some
non-AT&T may also be neon sets). If no neon sets are
connected to the circuit pack, the test continues to abort, but
no further action is required.
4. If there are no neon sets connected to the circuit pack, at
least one port needs to be translated with neon. To check if a
port is translated with neon, use display port PCSSpp to
determine the station extension of any station on this circuit
pack. Use display station <extension> to determine if the
port is administered with neon. The field “Message Waiting
Indicator:” must be set to “neon” for at least one of the
administered ports. If this field is not administered to “neon”
the test continues to abort. This is acceptable because not all
stations have neon lamps on their analog terminals. If none of
the terminals have neon lamps, the the test continues to
abort, but no further action is required.
1018
ABORT
(cont’d.)
5. Retry the command again.
6. If the test continues to abort with neon translated ports,
escalate the problem.
7. Retry the command at 1-minute intervals a maximum of 5
times.
8. If the test continues to abort, look for RING-GEN errors in the
Error Log. If an ABORT 1008 occurs for this test on other
circuit packs as well, then the ringing generator may be
defective or is not wired correctly (see errors for RING-GEN).
If it doesn’t occur on port test 48 for ANL-16-L, all four ring
phases are in use.
9. If the test to continues to abort, escalate the problem.
10. Retry the command again.
11. If the test continues to abort with neon translated ports,
escalate the problem.
Table 10-725.
TEST #220 Neon Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...