TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1687
555-233-123
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Services State
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
Signaling Link State (#1251)
This test is non-destructive.
This test checks the current state of the signaling link. The test looks at the
board-level translations, checks that the board is physically inserted, gets the
state of the D-Channel and service state of the port.
The test passes if the signaling link (D-Channel) is connected and operating
normally. The test fails if the board is not installed, the signaling link is
disconnected, or if the port is out of service. The test aborts otherwise.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
Destructive; ND = Nondestructive
Signaling Link State Check Test (#1251)
X
X
ND
Service State Audit Test (#256)
X
X
ND
Call State Audit Test (#257)
X
X
ND
ISDN Test Call Test (#258)
X
ND
Table 10-621.
TEST #1251 Signaling Link State Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1018
ABORT
The test is disabled.
1. Enable the test by entering “enable test #1251”.
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...