PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1285
555-233-123
1141
ABORT
The Packet Control circuit pack is not operational.
NOTE:
A busied-out Packet Control circuit pack can be
operational.
1. Determine if the Packet Control circuit pack has an active
major alarm (via the display alarm command). If it does,
follow the recommended repair procedures to retire the
alarm. Once the alarm is retired, the original command can
be retried.
2. If the Packet Control circuit pack does not have an active
major alarm, wait one minute and retry the original
command. If the Error Code 1141 is again observed, go to
the next step.
3. If the Packet Control circuit pack is not currently busied-out
and is on the active SPE, issue the busyout
packet-control C command. Issue the reset
packet-control C command. If the reset command fails,
follow the recommended repair procedures for Test #586. If
the reset command passes, issue the release
packet-control C command (if the Packet Control circuit
pack is on the active SPE), and then reissue the original
command.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1-3
FAIL
Maintenance was unable to establish a loop around link from the
Packet Control circuit pack back to itself, or was unable to
receive the data that was sent out over one side of the loop
around link.
1. Issue test packet-control C short command to retry the
test.
2. If the same error code is observed, maintenance software
automatically escalates the testing. No specific action is
required.
PASS
The Packet Control circuit pack can send and receive data
correctly.
Table 10-481.
TEST #585 Packet Control Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...