ASAI-EPT
Issue 4 May 2002
10-177
555-233-123
l. The switch software logs certain ASAI cause values. The cause value is
determined from the following formula:
— If the error type is greater than 3968, then the ASAI cause value is
equal to the error type minus 3968. The switch sent this value to the
endpoint.
— If the error type is less than 3968, then the ASAI cause code is
equal to the error type minus 3840. The switch sent this value to the
endpoint.
Table 10-57. ASAI Cause Values
Code
Explanation
Recommendation
0
Unrecognized
ASAI Protocol
Operation.
Requested ASAI protocol is not implemented by switch or
adjunct. Aux data field of error log entry contains protocol
identifier for unrecognized operation.
1. Consult switch and adjunct documentation to
determine which set of operations is supported by
switch and the adjunct. Adjunct administration turning
off operations not implemented by the switch may
resolve the problem.
34
No circuit or
channel
available
A resource on the switch is unavailable for a call. For BRI
endpoints, this cause value is not logged. For ASAI, this
condition means that there are no available trunks for an
outgoing call request.
1. Verify that the adjunct is administered to support the
trunk capabilities of the switch.
2. Investigate trunk group status by issuing the status
trunk command from the SAT or by requesting trunk
group query(ies) from the adjunct.
3. Perform trunk diagnostic procedures outlined in this
manual.
40
Resources not
available.
No available internal resources to service switch or adjunct
request. Exceeds system transaction capacity for adjunct
or switch.
1. May require re-engineering of adjunct services.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...