Maintenance Object Repair Procedures
555-233-123
10-1694
Issue 4 May 2002
1116
ABORT
The switch could not appropriately change the ISDN service
state.
1. Determine if a call is active on this ISDN Trunk-side BRI
trunk (use the status trunk command).
2. If not, check the Error and Alarm Logs for problems with
this TBRI-TRK MO.
1117
ABORT
ISDN B-channel maintenance message is already
outstanding.
1. Wait two minutes, then try again.
1118
ABORT
Far-end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Issue the status trunk command and try the test again.
1119
ABORT
The test call was aborted due to a normal call attempt on this
trunk. The test call is performed only if the trunk is idle.
1. Either wait for the normal call to terminate normally, or
force it to be dropped by using the busyout trunk
command.
1120
ABORT
The ISDN Trunk-side BRI trunk is in the ISDN
out-of-service/far-end state.
1. Try to change the service state via Test #256 (Service
State Audit Test). Then retry this test. However, the trunk
may be in the out-of-service/far-end state due to
problems at the far-end switch. If that is the case, no
remedial action can be taken at this end.
1122
ABORT
There is no test line number for the far-end switch.
1. Check the Trunk Group Administration form.
1123
ABORT
There is no Feature Access Code administration for this
Facility Test.
1. Check the Dial Plan and Feature Administration forms.
2012
None
2000
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2035
ABORT
The call has timed out, perhaps because of a lack of system
resources.
1. Wait 1 minute and try again.
Table 10-624.
TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...