ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member number of the port. Use the status station,
status attendant, or status trunk command to determine the
service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests.
(Refer to the “Status Commands” section in Chapter 10,
“Maintenance Commands and Trouble-Clearing Aids”, for a
full description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use
(off-hook), if the handset is plugged in and the port is not
busied out.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1018
ABORT
Test disabled via administration. Verify that the “Maintenance
Tests?” field on the Trunk Group Form is set to “n.” To enable
the test, issue the change trunk-group x command where “x”
equals the number of the trunk group to be tested. Then
change the entry in the “Maintenance Tests?” field on the form
to “y.”
2000
ABORT
Response to the test was not received within the allowable
time period.
1. Retry the command at 1-minute intervals for a maximum
of 5 times.
2100
ABORT
System resources required to run this test are not available.
This may be due to the port being seized.
1. This abort code is usually associated with tone-clock
(TONE-BD, TONE-PT, and TDM-CLK) resources. First,
clear any tone errors in the error log.
2. Retry the command at 1 minute intervals for a maximum
of 5 times.
Table 10-198.
TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...