RDIG-STA (Remote Digital Station)
Issue 4 May 2002
10-1447
555-233-123
5. Audits
As part of periodic maintenance, the Hardware Status Audit Test queries
programmable terminals to determine which levels and/or options are
being used. If the reported values are not equal to the administered values,
the system will initiate a terminal download action; however, this audit does
NOT check the parameters used for softkeys.
6. Activation of TTI
A terminal is downloaded automatically when it is activated using the
Terminal Translation Initialization (TTI) feature. Therefore, no special user
actions are required for TTI.
NOTE:
Plugging the station cord into a terminal does not automatically cause
the terminal to be downloaded. If this terminal has factory defaults or
if the terminal has been previously downloaded with parameters
different than those desired, use one of the demand download
actions described below to download the terminal.
Demand Download Actions
1. Busyout/Release Command
A maintenance demand busyout/release request for a station will cause the
terminal to be downloaded regardless of its previous download status.
2. Feature Access Code
A Refresh Terminal Parameters Feature Access Code can be used to
request a terminal download action. When this code is followed by a “#”,
the programmable parameters for the current terminal are downloaded
when the terminal goes on-hook. When this code is followed by an
extension, the programmable parameters for the specified station are
downloaded.
This Refresh Terminal Parameters Feature Access Code is assigned on
the second page of the feature-access-codes screen.
A confirmation is returned if the download request is accepted. A busy tone
is returned if the request is made from a different station when the target
station is off-hook.
As a result of an entry of a Refresh Terminal Parameters Facility Access
Code, the first three green call appearance LEDs on the 84xx 603x
terminal are turned on for three seconds, if the station was successfully
downloaded. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or demand
download actions. As described below, the status station and status
attendant screens can be used to check the download status of a specified
terminal.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...