Maintenance Object Repair Procedures
555-233-123
10-1582
Issue 4 May 2002
Switch Control EPN Maintenance Board Interface
Test (#324)
Loopback messages are sent to the Switch Control through the interface used for
EPN maintenance circuit pack messages. The messages are returned to the SPE
for verification through the same interface.
other
FAIL
The accuracy of Time of Day clock is not within limits.
1. Run the Short Test Sequence several times to make
sure the error is occurring consistently.
2. Replace the NetPkt or Netcon circuit pack at the
customer’s convenience (Standard system) or right
away (High or Critical Reliability system).
PASS
The Time of Day clock on the Switch Control circuit pack is
operating correctly.
Table 10-586.
TEST #324 Switch Control EPN Maintenance Board Interface Test
Error
Code
Test
Result
Description/Recommendation
1005
ABORT
The system does not contain an EPN, so this test is not
executed.
1030
ABORT
The component on which the test was to be run is on the
Standby SPE. This test may only be run on this component
when it resides on the Active SPE.
1. For recommended maintenance procedure, refer to
ABORT Error Code 1030 in STBY-SPE Maintenance
documentation.
32400
ABORT
Test disabled through software patch.
Continued on next page
Table 10-585.
TEST #95 Time of Day Clock Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...