Maintenance Object Repair Procedures
555-233-123
10-1760
Issue 4 May 2002
e. On an outgoing wink-start or delay-dial trunk, the wink time was too short
(less than 80ms) for a valid signal. Check the far-end PBX to ensure a
translation match at both ends.
f. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
g. This indicates that the trunk in question has been busied-out by
maintenance personnel.
h. This indicates that the circuit pack has been removed or has been insane
for more than 11 minutes. To clear the error, reinsert or replace the circuit
pack.
i. The rotary dial rate was too slow (less than eight pulses per second.)
Check the far-end PBX to ensure a translation match at both ends.
j. The rotary dial rate was too fast (more than 12 pulses per second.) Check
the far-end PBX to ensure a translation match at both ends.
k. The time between digits was too short (less than 300ms). Check the
far-end PBX to ensure a translation match at both ends.
l. This indicates that the trunk is still seized with an incoming call. The far-end
PBX is not releasing the trunk after the call is dropped. A Minor alarm is
generated every four minutes until the far-end PBX releases the trunk.
Check the far-end PBX for problems.
Once the trunk is released from the call, the severity of this problem is
decreased. If Error Type 1025 does not appear again, this means that the
problem has been corrected. Verify that Error Type 1025 does not reappear
in the Error Log.
m. Reorder message. Trunk could not be seized. This error causes the Tie
Trunk Seizure Test (#73) to run, and it is considered a problem only if the
Seizure Test fails (in which case Error Type 1793 also shows up). In this
case, the trunk may be placed in the “Ready-for-Service” state (shown as
“disconnected” by the status command), which allows only incoming calls.
Run the Tie Trunk Seizure Test and follow its outlined procedures.
n. Test calls made by the Automatic Transmission Measurement System
(ATMS) returned measurements that were outside the acceptable limits.
Use the list testcall detail command to examine specific transmission
parameters that are out of spec, and investigate the trunk for that kind of
noise. If the noise is acceptable, the limits administered on the “change
trunk” screen should be changed.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...