HYB-LINE (Hybrid Line)
Issue 4 May 2002
10-889
555-233-123
Notes:
a. Indicates a defective data link. An off-board problem was detected by port
circuit. Verify that the Hybrid set is connected and that the EPF test passes.
If data transmission problems are experienced, check for defective wiring
or a defective voice terminal, or move terminal closer to the switch (in
terms of feet of wire from the jack to the switch). If the problem still exists,
replace the circuit pack. Once the problem has been resolved, the alarm is
retired after a predetermined period of time.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors (if
any).
c. This error type is logged when the port in question is busied out by
maintenance personnel. Make sure port is released from busyout via
release port PCSSpp.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
e. This indicates that the EPF has been turned off due to an overcurrent
condition at the voice terminal. Check for defective wiring or a damaged
jack, and make sure the voice terminal is a Hybrid set. Once the problem
has been resolved, the alarm is retired after a predetermined period of
time.
f. This indicates that the voice terminal has probably been disconnected or
that there is a problem in the wiring to the terminal. Make sure that the
voice terminal is connected or check for defective wiring to the voice
terminal.
g. Note that Error Types 769 and 1281 by themselves create Warning alarms
only, but if both are present, a Minor alarm is logged.
h. This indicates that there is something wrong with the data link to the voice
terminal. An in-line maintenance error has generated an off-board warning.
Ignore it if there are no complaints. Otherwise, make sure the voice
terminal is connected, check for defective wiring, check for a defective
voice terminal, and move voice terminal closer to the switch (in terms of
feet of wire from the jack to the switch). If the problem still exists, replace
the circuit pack.
i. This indicates that the station went off-hook while in the disconnect state.
Use status station to determine the state of the station. The off-hook
should have moved the station to in-service. No system technician action is
necessary.
j. This is the code that is generated when the link between the circuit pack
and the voice terminal is successfully reset. No system technician action is
necessary.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...