ISDN-SGR (ISDN-PRI Signaling Group)
Issue 4 May 2002
10-967
555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Primary Signaling Link Hardware Check, for
example, you may also clear errors generated from other tests in the testing
sequence.
3928
A call was denied because
of a basic incompatibility
between the type of call and
either the facilities selected
by the routing pattern or the
called user itself.
This error might be helpful as a clue if the
customer complains of receiving unexpected
intercept tone after accessing ISDN trunks or
PRI endpoints. Determine the trunk group
from the circuit pack and port number (in the
aux data field) and then check the BCC fields
of the pertinent routing patterns. Also,
investigate whether or not the calling and
called endpoints are compatible (for
example, some ISDN switches may not allow
a voice station to call a data extension).
3942
Timer expiry: T310
time-out, no answer to
CALL PROCEEDING.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Primary Signaling Link Hardware Check (#636)
X
X
ND
Secondary Signaling Link Hardware Check (#639)
X
X
ND
Layer 2 Query Test (#647)
X
X
ND
Remote Layer 3 Query Test (#637)
X
X
ND
Table 10-349.
Descriptions of Error Codes 3842-3942 — Continued
Error
Code
Description
Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...