Maintenance Architecture
555-233-123
1-4
Issue 4 May 2002
7. Find the DID-TRK MO in the Maintenance Object chapter of the
appropriate maintenance book.
8. In the first table look up the initial command to run in the MAJOR row of the
table (Step 4 indicated that a DID trunk in slot 10, carrier C has a MAJOR
alarm).
9. Type test port 01C1008 long and press
Enter
.
“01C1008” is the address of the alarmed port (
and
10. While the port test is running, look up the Error Type (1537 from
) in the DID Trunk Error Log Entries table (example below).
11. Since the Test to Clear Value (
test port 01C1008 sh r 1) is very similar to the
initial test you ran in Step 11, wait for the results of the port test.
12. When the port test finishes, the following screen appears (
):
Screen 1-4.
Test Results screen
13. Find the Port Diagnostic Test (#35 from
Test No.
) in the DID-TRK section
of the Maintenance book. Note the
Error Code
(61472).
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs), C is the carrier designation (A, B,
C, D, or E), SS is the number of the slot in which the circuit pack resides (01 to 21), and pp is the
two digit port number (01, 02,...).
Full Name of MO
DID-TRK
MAJOR
2
2.
A MAJOR alarm on a trunk indicates that alarms on these trunks are downgraded by the set options
command and that at least 75% of the trunks in this trunk group are alarmed.
test port UUCSSpp long
DID Trunk
DID-TRK
MINOR
test port UUCSSpp long
DID Trunk
DID-TRK
WARNING
test port UUCSSpp
DID Trunk
Table 1-2. DID Trunk Error Log entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
1537
Port Diagnostic (#35)
MAJ/MIN/WRN
OFF
test port UUCSSpp sh r 1
3840(k)
40965
None
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1008 DID-TRK 35 FAIL 61472
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...