Maintenance Object Repair Procedures
555-233-123
10-1792
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
Table 10-654.
Tone-Clock Circuit Pack Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test tone-clock PC sh
1(a)
0
Circuit pack
removed or
SAKI Sanity
Test (#53)
MINOR
ON
18(b)
0
busyout
tone-clock PC
WARNING
OFF
release tone-clock PC
23(c)
0
None
WARNING
OFF
125(d)
None
MINOR
ON
126(e)
None
MINOR
ON
257
65535
Control Channel
Test (#52)
MINOR
ON
test tone-clock PC r 20
257(f)
Any
None
513(g)
Any
None
769(h)
4358
None
1025(i)
4363
NPE Audit Test
(50)
test tone-clock PC sh
1538(j)
Any
None
MINOR
ON
2049(k)
0
Clock Health
Inquiry Test
(#46)
MAJOR
ON
set tone-clock PC
override
2305(k)
0
Clock Health
Inquiry Test
(#46)
MAJOR
ON
set tone-clock PC
override
2561(l)
Any
None
MAJOR
ON
3329
(m)
0
None
MINOR/
WARNING
2
2
Minor alarms on this MO may be downgraded to Warning alarms based on the value
used in the set options command.
OFF
set tone-clock PC
3840(n)
Any
None
3848(o)
0
Clock Health
Inquiry Test
(#46)
set tone-clock PC
override
3872(p)
0
None
set tone-clock PC
override
3999
(q)
Any
None
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...