ADX16D-P (16-Port AUDIX Digital Port)
Issue 4 May 2002
10-33
555-233-123
7
FAIL
Conference Test failed on the primary channel. In some
cases, users may not notice a disruption in service. In extreme
cases, the conferencing feature may not work at all.
14
FAIL
The primary voice channel is not transmitting properly. User
impact may range from no noticeable effect to loss of use of
this port.
15
FAIL
The control channel between the processor and AUDIX is not
transmitting properly. User impact may range from no
noticeable effect to loss of use of this port. This failure could
also be disruptive to other users.
16
FAIL
The secondary voice channel is not transmitting properly. User
impact may range from no noticeable effect to loss of use of
this port.
None
FAIL
The test failed for reasons external to the AUDIX.
1. Run circuit pack tests to check the tone generator circuit
pack and the tone detector circuit pack by using the test
board PCSS s command.
2. Resolve any problems detected on the tone generator
circuit pack or tone detector circuit pack.
3. If the tone generator and tone detector circuit packs are
functioning properly, and if the test still fails, replace the
AUDIX (see caution at the beginning of this section).
PASS
Voice and Control Channel Local Loop test passed. All
channels are transmitting properly.
1. To be sure that this is not an intermittent problem, repeat
this test up to 10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-12. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...