Maintenance Object Repair Procedures
555-233-123
10-1268
Issue 4 May 2002
Table 10-473.
Test #571 Packet Control Bus Loop Around Test
Error
Code
Test
Result
Description/Recommendation
1022
ABORT
No Packet Control circuit pack exists in this port network.
1. This test gives information only for the PPN. Ignore results
from this test whenever it is run in other port networks.
1024
ABORT
The Packet Control circuit pack is in use by Packet Control
maintenance at this time. The test cannot be completed until the
Packet Control circuit pack becomes available.
1. Wait for Packet Control maintenance to finish using the
Packet Control circuit pack. (The green LED goes out.)
2. Re-enter the command.
1141
ABORT
The Packet Control circuit pack is out-of-service.
1. Determine if the Packet Control circuit pack is busied out (this
is indicated by an Error Type 18 logged against PKT-CTRL). If
the pack is busied out, release the pack by entering the
release packet-control command. Then re-enter the
command.
2. If the Packet Control circuit pack is NOT busied out, refer to
PKT-CTRL Maintenance documentation for recommended
repair procedures.
1143
ABORT
This test is run only in high or critical reliability systems.
1. Ignore results from this test when it is run in a high or critical
reliability system.
2000
ABORT
The test timed-out while waiting for the packet to be returned from
the loop around.
1. Re-enter the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, check for problems with the
Packet Control (look for PKT-CTRL errors in the Error and
Alarm Logs).
2076
ABORT
The parity error check circuitry on the Packet Control circuit pack
is not functioning correctly.
1. Run the test again.
2. If the same abort occurs again, refer to PKT-CTRL to attempt
to correct the fault.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...