Maintenance Object Repair Procedures
555-233-123
10-534
Issue 4 May 2002
2. NPE Crosstalk Test—verifies the switch connection operation of the circuit
pack. The test also verifies that the trunk circuitry only talks on the selected
time slot on the TDM Bus and never crosses over to time slots reserved for
other connections.
3. Port Diagnostic Test—the battery feed circuitry is tested for hook detection.
4. Port Audit Update Test—updates the DID translation information on
individual ports of the DID trunk. The port translation data consists of
signaling parameters whose values depend on the CO switch connected to
the trunk. These parameters include:
■
wink (signal indicating PBX is ready to receive digits) or immediate
start
■
dial tone or rotary dialing trunk
■
rotary dialing inter-digit timing
■
network balance R/RC
■
disconnect timing
Additional in-line testing is performed while a call is in progress. Thus, in-line
errors may occur during operation. See Error Log table for a description of these
errors. These errors may be reproduced by using the trunk (that is, placing a call)
and checking their occurrence in the Hardware Error Log.
Problems detected during signaling may be caused by faults off-board (in the CO
switch or connections) for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an
incoming call seizes the port which is being tested by maintenance, the test is
aborted, and the incoming call proceeds.
For transmission and signaling standard specification, refer to Digital PBX
Standards document RS4648.
Hardware Error Log Entries and Test to Clear
Values
Table 10-196.
DID Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
WRN
OFF
1 (b)
57476
None
WRN
OFF
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...