MMI-BD
Issue 4 May 2002
10-1117
555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. The circuit pack stopped functioning or it was physically removed from the
system. The alarm logs approximately 11 minutes after the circuit pack has
been removed and/or the SAKI Sanity Test (#53) fails.
If the circuit pack is in the system and the red LED is on, follow the
instructions for a red alarm in
‘‘Control and port circuit pack status LEDs’’
in
Chapter 7, ‘‘LED Interpretation’’
. Also, see “Handling Common Port Circuit
Packs.”
b. This circuit pack has been busied out using the busyout board PCSS
command.
c. There are more than four MMI circuit packs in the system. Remove the
circuit pack that generated the error in the error log by locating the slot
indicated by the error.
d. Indicates transient communication problems between the switch and this
circuit pack. Execute the test board PCSS command and refer to the
repair procedures for the Control Channel Looparound Test (#52) in the
XXX-BD section.
Table 10-419.
MMI-BD Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test board PCSS sh r 1
1 (a)
Any
None
MIN
ON
18 (b)
0
Busyout board PCSS
WNG
OFF
release board PCSS
217 (c)
0
None
WNG
ON
257 (d)
65535
Control Channel Loop Test (#52)
MIN
ON
test board PCSS r 3
513 (e)
4352
to
4357
Uplink error from pack
769 (f)
Any
MMI Synchronization Status
Test (#1123)
None
1281 (g)
Any
Circuit Pack Restart Test (#594)
MAJ
ON
1538 (h)
Any
Software detected error
MIN
ON
1793 (i)
ANY
TSI XTalk (#6)
MIN
ON
test board PCSS l r 3
2049 (j)
Any
TSI Loop (#1108)
MAJ
ON
test board PCSS l r 3
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...