Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-380
Issue 4 May 2002
Field descriptions
status processor-channel
This command displays the status of the specified processor channel and the
values of its various counters. A processor channel is 1 of 64 logical channels
associated with an SCI link. Each processor channel terminates in the switch
processing element with a session.
Extension
PRI endpoint extension
Width
Administered number of B-channels associated with the
specified PRI endpoint
Signaling Group
ID
ID number of the signaling group that handles the signaling for
the ports in the specified PRI endpoint
Originating Auto
Restoration
Administered option for the auto restore feature (restores calls
originated from this PRI endpoint in the case of network
failure):
y
= restoration option enabled
n
= restoration option disabled
B-Channels Active
The number of B-channels active on a call
B-Channels Idle
The number of B-channels in the in-service/idle state
Port
Port locations (cabinet-carrier-slot-circuit) for each of the
B-channels making up the PRI endpoint.
Service State
Service state of the B-channels:
in-service/active, in-service/idle, out-of-service-NE,
out-of-service-FE, maint-NE/active, maint-FE/active,
maint-NE/idle, and maint-FE/idle.
NE (Near End) and FE (Far End) refer to which “end” of the
B-channel has placed the facility in the current state. NE
refers to the switch and FE refers to the PRI terminal adapter
(or any device that terminates the D-channel signaling on the
facility).
Test In Progress
Whether or not there is any current maintenance testing on
the port.
Connected Port
Connected port location (cabinet-carrier-slot-circuit) for each
of the B-channels active on a call.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
status
processor-
channel
channel
number
Processor channel number (1-64).
Report sent to printer
Examples:
status processor-channel 1
status processor-channel 10
status processor-channel 64
status processor-channel 64 print
init
inads
craft
cust
rcust
bcms
browse
none
none
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...