DAT-LINE (Data Line)
Issue 4 May 2002
10-511
555-233-123
Audit Update Test (#36)
This audit makes sure that the hardware state of the Data Line is consistent with
the system translations. When this audit is run, the port is queried for the
switchhook state, and the software state is updated according to the returned
value. Also, the data line options are sent down to the port.
Table 10-188.
TEST #36 Audit Update Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals for a maximum
of 5 times.
2. Escalate the problem if the test continues to abort.
1006
ABORT
The test did not run due to an already existing error on this
port (Error Type 769).
1. Refer to the procedure for Error Type 769. If Error Type
769 still occurs on this port, replace the circuit pack.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
7
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
The hardware port state is consistent with the software state.
User-reported troubles on this port should be investigated
using other port tests, examining the ADU, external wiring,
and customer equipment.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...