UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1935
555-233-123
This test is only be executed on TN464F or later suffix UDS1 circuit packs
administered for 24-channel operation (1.544 bit rate).
If the 120A1 CSU Module or the 401A T1 Sync Splitter is not physically installed,
the status LEDs are always off and this test aborts.
Table 10-690.
TEST #1227 ICSU Status LEDs Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1005
ABORT
The ICSU Status LEDs test can not be executed for the current
configuration. The test applies only to TN464F or later UDS1
circuit packs administered for 24-channel operation (1.544 bit
rate).
1. If the circuit pack is a TN464F or later suffix UDS1 circuit
pack, then retry the command.
1951
ABORT
The ICSU Status LEDs Test can not be executed because a
120A1 or later suffix CSU Module or a 401A or later suffix T1
Sync Splitter is not physically installed. If using a 120A1 CSU
Module or the 401A T1 Sync Splitter, physically connect it to the
UDS1-BD board on the back of the port carrier. Otherwise,
ignore this abort.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
2500
ABORT
Internal system error.
1. Retry the command.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...