BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-305
555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors associated with the circuit pack and port first. Clearing these
error codes first may also clear errors generated against the endpoint. When all
circuit pack and port errors have been cleared, and errors still exist against the
endpoint, always investigate errors in the order they are presented in the table
below. By clearing error codes associated with the Signaling Link Status Test, for
example, you may also clear errors generated from other tests in the testing
sequence.
65
Bearer Service
Not Implemented
Requested service not implemented in switch or
endpoint.
69
Requested
Facility Not
Implemented
Requested service not supported in switch or
endpoint.
1. Consult switch and endpoint documentation
to determine service support.
2. If Step 1 does not resolve the problem,
escalate to the next tier.
ADJUNCT/SWITCH ERROR CONDITIONS
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency
between the switch and the adjunct. See the
CallVisor protocol reference manual.
2. If step 1 does not resolve the problem,
escalate to the next tier.
Table 10-120.
ISDN-BRI Cause Values — Continued
Code
Explanation
Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...